Differential Absorption Carbon monOxide Measurement

The in‐situ diode laser spectrometer system, referred to by its historical name DACOM, includes three tunable diode lasers providing 4.7, 4.5, and 3.3 μm radiation for accessing CO, N2O, and CH4 absorption lines, respectively. The three laser beams are combined by the use of dichroic filters and are then directed through a small volume (0.3 liter) Herriott cell enclosing a 36 meter optical path. As the three coincident laser beams exit the absorption cell, they are spectrally isolated using dichroic filters and are then directed to individual detectors, one for each laser wavelength. Wavelength reference cells containing CO, CH4, and N2O are used to wavelength lock the operation of the three lasers to the appropriate absorption lines. Ambient air is continuously drawn through a Rosemount inlet probe and a permeable membrane dryer which removes water vapor before entering the Herriott cell and subsequently being exhausted via a vacuum pump to the aircraft cabin. To minimize potential spectral overlap from other atmospheric species, the Herriott cell is maintained at a reduced pressure of ~90 Torr. At 5 SLPM mass flow rate, the absorption cell volume is exchanged nominally twice per second. Frequent but short calibrations with well documented and stable reference gases are critical to achieving both high precision and accuracy. Calibration for all species is accomplished by periodically (~4 minutes) flowing calibration gas through this instrument. Measurement accuracy is closely tied to the accuracy of the reference gases obtained from NOAA/ESRL, Boulder, CO. Both CO and CH4 mixing ratios are provided in real-time to investigators aboard the DC‐8.

Measurements: 
Point(s) of Contact: 

Focused Cavity Aerosol Spectrometer

The FCAS II sizes particles in the approximate diameter range from 0.07 mm to 1 mm. Particles are sampled from the free stream with a near isokinetic sampler and are transported to the instrument. They are then passed through a laser beam and the light scattered by individual particles is measured. Particle size is related to the scattered light. The data reduction for the FCAS II takes into account the water which is evaporated from the particle in sampling and the effects of anisokinetic sampling (Jonsson et al., 1995).

The FCAS II and its predecessors have provided accurate aerosol size distribution measurements throughout the evolution of the volcanic cloud produced by the eruption of Mt. Pinatubo. (Wilson et al., 1993). Near co-incidences between FCAS II and SAGE II measurements show good agreement between optical extinctions calculated from FCAS size distributions and extinctions measured by SAGE II.

Accuracy: The instrument has been calibrated with monodisperse aerosol carrying a single charge. The FCAS III and the electrometer agree to within 10%. Sampling errors may increase the uncertainty but a variety of comparisons suggests that total uncertainties in aerosol surface are near 30% (Jonsson, et al., 1995).

Precision: The precision equals 1/ÖN where N is the number of particles counted. In many instances the precision on concentration measurements may reach 7% for 0.1 Hz data. If better precision is desired, it is necessary only to accumulate over longer time intervals.

Response Time: Data are processed at 0.1 Hz. However, the response time depends upon the precision required to detect the change in question. Small changes may require longer times to detect. Plume measurements may be processed with 1 s resolution.

Weight: Approximately 50 lbs.

Instrument Type: 
Aircraft: 
Point(s) of Contact: 

Condensation Nuclei Counter

The CNC counts particles in the approximate diameter range from 0.006 m to 2 m. The instrument operates by exposing the articles to saturated Flourinert vapor at 28 C and then cooling the sample in a condenser at 5 C. The supersaturation of the vapor increases as it is cooled and the vapor condenses on the particles causing them to grow to sizes which are easily detected. The resulting droplets are passed through a laser beam and the scattered light is detected. Individual particles are counted and are referred to as condensation nuclei (CN). Two CN Counters are provided in the instrument. One counts the particles after sampling from the atmosphere and the second counts particles that have survived heating to 192C. Lab experiments show that pure sulfuric acid particles smaller than 0.05 mm are volatilized in the heater. The heated channel detects when small particles are volatile and permits speculation about the composition. The CNC II contains an impactor collector which permits the collection of particles on electron microscope grids for later analysis. The collector consists of a two stages. In the first stage the pressure of the sample is reduced by a factor of two without loosing particles by impaction on walls. The second stage consists of a thin plate impactor which collect efficiently even at small Reynolds numbers. The system collects particles as small as 0.02 m at WB-57 cruise altitudes. As many as 25 samples can be collected in a flight.

Instrument Type: 
Measurements: 
Point(s) of Contact: 

14-channel NASA Ames Airborne Tracking Sunphotometer

AATS-14 measures direct solar beam transmission at 14 wavelengths between 354 and 2139 nm in narrow channels with bandwidths between 2 and 5.6 nm for the wavelengths less than 1640 nm and 17.3 nm for the 2139 nm channel. The transmission measurements at all channels except 940 nm are used to retrieve spectra of aerosol optical depth (AOD). In addition, the transmission at 940 nm and surrounding channels is used to derive columnar water vapor (CWV) [Livingston et al., 2008]. Methods for AATS-14 data reduction, calibration, and error analysis have been described extensively, for example, by Russell et al. [2007] and Shinozuka et al. [2011]. AATS-14 measurements of spectral AOD and CWV obtained during aircraft vertical profiles can be differentiated to determine corresponding vertical profiles of spectral aerosol extinction and water vapor density. Such measurements have been used extensively in the characterization of the horizontal and vertical distribution of aerosol optical properties and in the validation of satellite aerosol sensors. For example, in the Aerosol Characterization Experiment-Asia (ACE-Asia), AATS measurements were used for closure (consistency) studies with in situ aerosol samplers aboard the NCAR C-130 and the CIRPAS Twin-Otter aircraft, and with ground-based lidar systems. In ACE-Asia, CLAMS (Chesapeake Lighthouse & Aircraft Measurements for Satellites, 2001), the Extended-MODIS-λ Validation Experiment (EVE), INTEX-A, INTEX-B, and ARCTAS, AATS results have been used in the validation of satellite sensors aboard various EOS platforms, providing important aerosol information used in the improvement of retrieval algorithms for the MISR and MODIS sensors among others.

Instrument Type: 
Measurements: 
Aircraft: 
DC-8 - AFRC, J-31, P-3 Orion - WFF, Convair 580 NRC, Twin Otter International, C130H - WFF
Point(s) of Contact: 

Airborne Raman Ozone, Temperature, and Aerosol Lidar

This is a stratospheric lidar which is configured to fly on the NASA DC-8. It is a zenith viewing instrument, which makes vertical profile measurements of ozone, aerosols and temperature. Stratospheric ozone can be measured at solar zenith angles greater than ~30 degrees, while temperature and aerosols require SZA > 90 degrees. The SNR is maximized under dark coonditions. The measurement of Near-field water vapor measurements is being investigated and could be readily implemented. The instrument utilizes a XeCl excimer laser and a Nd-YAG laser to make DIAL, Raman DIAL, and backscatter measurements. A zenith viewing 16" telescope receives the lidar returns.

Instrument Type: 
Aircraft: 
Point(s) of Contact: 