Hawaii Group for Environmental Aerosol Research

1) Time of Flight Aerosol Mass Spectrometer (ToF-AMS)

Total and single particle characterization of volatile aerosol ionic and organic components (50-700nm). Uncertainty depends on species and concentration.

2) Single Particle Soot Photometer (SP2)

Single particle measure of BC (soot) mass in particles and determination of mixed particle size and non-BC coating using laser scattering and incandescence. 70-700nm. Single particle counting up to 10,000 per sec.

3) A size-resolved thermo-optic aerosol discriminator (30 s avg.):

Aerosol size distribution from 0.12 up to 7.0 μm, often where most aerosol mass, surface area and optical effects are dominant. Uses a modified Laser Optical Particle Counter (OPC) and computer controlled thermal conditioning system is used upstream (airstream dilution dried). Characterizes aerosol components volatile at 150, 300 and 400C and refractory aerosol at 400C (sea salt, dust and soot/flyash). (Clarke, 1991, Clarke et al., 2004). Uncertianty about 15%

4) Condensation Nuclei - heated and unheated (available at 1Hz)

Two butanol based condensation nuclei (CN) counter (TSI 3010) count all particles between 0.01-3.0 um. Total CN, refractory CN (those remaining at 300C after sulfate is removed) and volatile CN (by difference) are obtained as a continuous readout as a fundamental air mass indicator (Clarke et al. 1996). Uncertainty ~ 5%.

5) Aerodynamic Particle Sizer – (APS-TSI3320) – (<5min/scan)

To further characterize larger “dry” particles, including dust, an APS is operated which sizes particles aerodynamically from 0.8 to 20 μm into 50 channels. Uncertainty~10%.

6) Differential Mobility Analyzer with thermal conditioning – (<3 min/scan)

Volatility tandem thermal differential mobility analyzer (VTTDMA) with thermal analysis that provides size information (mass, surface area, number distributions) and their state of mixing over the 0.01 to 0.3μm size range (Clarke et al., 1998, 2007) for sampling times of about 1-3 minutes. Uncertainty ~10%

7) Nephelometer (10-7 m-1 detection for 60s avg., recorded every 1 sec.)

A 3 wavelength nephelometer (450, 550, 700nm) is used for total scattering and submicrometer scattering values using a Radiance Research single wavelength nephelometer (and thereby coarse dust scattering by difference).

8) Two Particle Soot Absorption Photometers (PSAP-Radiance Research; detection <0.1μg m-3 for 5 min. avg. )

The PSAP is used to quantify the spectral light absorption coefficient of the total and submicron aerosol (eg. soot, BC) at three wavelengths (450, 550, 660nm).

9) Humidity Dependent Light-Scattering (10-6 m-1 detection for 60s avg.; recorded every 1 s)

Two additional Radiance Research single-wavelength nephelometers are operated at two humidities (high/low) to establish the humidity dependence of light scattering, f(RH).

Point(s) of Contact: 

Airborne Multi-angle SpectroPolarimeter Imager

The Multiangle SpectroPolarimetric Imager, or AirMSPI, was a candidate for the multi-directional, multi-wavelength, high-accuracy polarization imager identified by the National Research Council's Earth Sciences Decadal Survey as one component of the notional Aerosol-Cloud-Ecosystem, or ACE, mission. The ACE spacecraft was planned to characterize the role of aerosols in climate forcing, especially their impact on precipitation and cloud formation. Forcing is the process by which natural mechanisms or human activities alter the global energy balance and “force” the climate to change. The unresolved effects of aerosols on clouds are among the greatest uncertainties in predicting global climate change. AirMSPI is conceptually similar to JPL’s Multiangle Imaging SpectroRadiometer, or MISR, carried on NASA’s EOS Terra spacecraft, but with some important additions. The new camera design extends the spectral range to the ultraviolet and shortwave infrared (from 446–866 nm to 355–2130 nm), increases the image swath (from 360 km to 680 km) to achieve more rapid global coverage (from 9 days to 4 days), and adds high-accuracy polarimetry in selected spectral bands. Like MISR, a suite of AirMSPI cameras would view Earth at a variety of angles, with an intrinsic pixel size of a few hundred meters, which for certain channels would be averaged up to about 1 kilometer.
An advanced version of this instrument is currently in development, called AirMSPI-2. 

Instrument Type: 
Measurements: 
Aircraft: 
Point(s) of Contact: 

Advanced Microwave Precipitation Radiometer

The AMPR is a total power passive microwave radiometer producing calibrated brightness temperatures (TB) at 10.7, 19.35, 37.1, and 85.5 GHz. These frequencies are sensitive to the emission and scattering of precipitation-size ice, liquid water, and water vapor. The AMPR performs a 90º cross-track data scan perpendicular to the direction of aircraft motion. It processes a linear polarization feed with full vertical polarization at -45º and full horizontal polarization at +45º, with the polarization across the scan mixed as a function of sin2, giving an equal V-H mixture at 0º (aircraft nadir). A full calibration is made every fifth scan using hot and cold blackbodies. From a typical ER-2 flight altitude of ~20 km, surface footprint sizes range from 640 m (85.5 GHz) to 2.8 km (10.7 GHz). All four channels share a common measurement grid with collocated footprint centers, resulting in over-sampling of the low frequency channels with respect to 85.5 GHz.